transformers
e6fc54bd - [serge] Fix 2 integration tests for model `seamless_m4t_v2` failing with `output_mismatch` (list output differs (2)) (#48553)

Commit
2 days ago
[serge] Fix 2 integration tests for model `seamless_m4t_v2` failing with `output_mismatch` (list output differs (2)) (#48553) * [serge] Fix 2 integration tests for model `seamless_m4t_v2` failing with `output_mismatch` (list output differs (2)) * Fix the root cause instead of flattening the compared sequences `test_to_rus_speech` did not fail because of a `squeeze()` quirk: #48425 changed the `input_audio` fixture from `audio=[input_features.tolist()]` (one 2-channel sample, batch size 1) to `audio=audio_array.tolist()` (two mono samples, batch size 2), so `output.sequences` became `[2, N]` and `tolist()` nested. Flattening cannot make the test pass -- it produces 2N tokens against an 8-token expectation -- and the two following assertions on `unit_sequences` and `waveform` stay nested as well. Restore the batch-1 input the expected values were computed with. The sample is passed as a tensor because `make_list_of_audio` (the validation that made #48425 necessary) only accepts arrays, tensors or lists of floats, not a triply-nested list. The resulting `input_features` are bit-identical to the pre-#48425 ones (verified: both `(1, 62, 160)`, `torch.equal` on features and attention mask). Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> --------- Co-authored-by: serge[bot] <serge[bot]@users.noreply.github.com> Co-authored-by: Tarek Ziade <tarek@ziade.org> Co-authored-by: Claude Opus 5 (1M context) <noreply@anthropic.com>
Parents
Loading