Partition AutoEP expert parameters per layer under ZeRO-3 (#8424)
### Problem
When a model created under `zero.Init` is passed to
`deepspeed.initialize`, AutoEP creates new local-expert tensors while
replacing MoE layers. ZeRO-3 previously converted those tensors only
after every layer had been replaced, so full replacement-expert storage
accumulated across layers and increased the initialization peak.
This addresses the initialization-memory behavior described as problem 1
in #8353. It does not change the independent debug-map retention
behavior covered by #8356.
### Approach
After each AutoEP layer is repacked, copied, tagged, and installed,
resolve its expert-data-parallel group and immediately pass only its
newly created expert parameters through the existing ZeRO conversion
helper. Optimizer classification and grouping use the experts' ZeRO
logical shape and size after partitioning. Existing source gathers,
router/shared/dense placement, and batched output-recorder retargeting
remain unchanged. The later ZeRO setup already skips parameters
converted by this step.
---------
Signed-off-by: Masahiro Tanaka <tanaka.masahiro@gmail.com>