[AutoEP] Run staged expert weight gradients with ZeRO-3 (#9115)
Follow-up to #9114 (stacked on its branch; proposal in #9113): lets
`deferred_dw_flush_period` run with ZeRO stage 3.
This PR was written with AI assistance (Claude Code). I have reviewed
the code line by line, wrote part of it and signed off the commit. It
depends on #8981, which is now merged; the branch is rebased onto it and
the results below were measured on the`c76a7ea55`, which has the same
tree as the then signed-off head `b708bbfc8`. The branch has since been
rebased onto #9114's review fixes and a review fix added (head
`e27a91cc9`); the results on that head are listed first below.
## How we support ZeRO-3, and what each part does:
1. **Gradient hook with no gradient** (this PR, `zero/stage3.py`, core,
4 lines). On a backward that stages, the expert weights are in the graph
but get no gradient, and the per-parameter hook still fires.
`reduce_independent_p_g_buckets_and_remove_grads` now returns early for
a `None` gradient, as #9114 does for ZeRO-2.
2. **Stale accumulation buffer** (not in this PR; fixed by #8981,
merged). `partition_grads` overwrote a parameter's gradient partition
only in micro step 0 and added afterwards. A staged expert weight gets
its first gradient of a window in a later micro step, so it was added
onto the previous window's gradient. #8981 makes a parameter's first
gradient after `step()` overwrite its partition, which is what staging
needs. I did not duplicate that fix here.
3. **Unaligned weights** (this PR, `moe/ep_experts.py`). ZeRO-3 hands a
module its weights as slices of a gathered buffer that need not start on
the 16-byte boundary the CUDA `torch._grouped_mm` requires
(`RuntimeError: expected data_ptr to be aligned to 16 bytes`). On this
machine that failed for `use_grouped_mm=true` with ZeRO-3 with or
without staging. `_grouped_mm_weight` clones a weight only when it is
unaligned; the plain, fused gate+up and deferred paths use it. The
deferred function saves the parameters and derives the aligned weights
again in the backward, for which ZeRO-3 gathers them, so the gathered
weights are not kept allocated between a layer's forward and its
backward (e27a91cc9; with `gate_up_impl="fused"` the packed gate+up copy
is still kept, see Review fixes).
The ZeRO-stage rejection in `auto_ep_config.py` is removed and the docs
updated.
## Open design question
#8277 solved the same alignment failure for ZeRO-1/2 by padding the flat
buffer (`zero_optimization.parameter_alignment`), explicitly without
copying misaligned parameters. Item 3 here takes the other route for
ZeRO-3: a weight-sized copy per forward, only when a gathered weight is
unaligned. Extending the padding to ZeRO-3's gathered buffers would
avoid the copy but is a larger change to `partition_parameters.py`.
Maintainers should choose; item 3 can be dropped from this PR if padding
is preferred.
## Duplicate-work check
Searched open and closed issues/PRs for "deferred dw", "tgmm", "expected
data_ptr to be aligned", "grouped_mm data_ptr aligned 16 bytes",
"partition_grads micro_step_id stale gradient". Found #8981 (covers item
2; not duplicated, since merged) and #8276/#8277 (alignment for ZeRO-1/2
only; see above). Sibling paths: the ZeRO-2 hook guard is in #9114;
ZeRO-1/2 passed the same two-window parity test without further changes.
## Tests run
Hardware: 3x NVIDIA H200 (143 GiB), driver 595.112.07, PyTorch
2.8.0+cu129, Python 3.12, `DS_SKIP_CUDA_CHECK=1` (system CUDA toolkit
13.2).
On `e27a91cc9` (rebased onto #9114 at `6ee0cbb9a`, which returns staged
gradients in the same backward on every rank, plus the weight-retention
fix):
```
pytest unit/v1/moe/test_autoep_grad_parity.py -k TestAutoEPDeferredDwParity
-> 8 passed (2 GPUs, comm backend, accumulation 4, flush period 3, two optimizer steps)
expert parallel 2, ZeRO 0/1/2/3: staged vs. unstaged parity
expert parallel 1 (both ranks replicate every expert, different data), ZeRO 1/2/3, 12 rows per expert:
ranks flush early in different backwards and still reduce together
plus the step() guard
pytest unit/v1/moe/test_autoep_expert_activation.py -k "TestDeferredDwStaging or slot or overlap"
-> 48 passed (1 GPU, bf16)
pytest unit/v1/zero/test_zero3_unused_param_grads.py
-> 21 passed, 7 skipped (2 GPUs)
pytest unit/v1/moe/test_autoep_expert_activation.py unit/module_inject/test_auto_ep_comm.py unit/v1/moe/test_autoep_unit.py
-> 387 passed, 50 skipped (CPU, PyTorch 2.10.0+cpu)
pre-commit run --files <changed files>
-> passed
```
The rebase conflicted in `docs/_pages/config-json.md` and
`test_autoep_grad_parity.py`; beyond resolving them, this PR now runs
#9114's replicated-expert test under ZeRO-3 as well, since ZeRO-3 also
reduces a gradient in the backward that returns it. The results below
were not repeated on this head.
Rerun on `c76a7ea55` (rebased onto master with #8981):
```
pytest unit/v1/moe/test_autoep_grad_parity.py -k DeferredDw
-> 5 passed: staged vs unstaged gradients for ZeRO 0/1/2/3, plus the step() guard
(2 GPUs, expert parallel 2, accumulation 4, flush period 3, two optimizer steps)
pytest unit/v1/moe/test_autoep_expert_activation.py -k DeferredDwStaging
-> 39 passed (1 GPU; includes the new unaligned-weights test)
pytest unit/v1/zero/test_zero3_unused_param_grads.py
-> 21 passed, 7 skipped (the tests added by #8981)
pytest unit/module_inject/test_auto_ep_comm.py
-> 65 passed, 3 skipped, 6 failed; the same 6 fail on unmodified master here
(this torch build has no CPU `torch._grouped_mm`)
```
A single-GPU ZeRO-3 script over optimizer steps with flush periods 2/3/4
gave staged gradients within 0.8% of the largest unstaged gradient
element (bf16 rounding). Before #8981 the same script gave 198%, and the
ZeRO-3 case of the parity test failed at the second window.
Run before the rebase and not repeated on this head:
`unit/v1/moe/test_autoep_integration.py` (7 passed, 3 skipped), a
`unit/v1/zero/test_zero.py` ZeRO-3 subset (40 passed, 1 skipped), and
`pre-commit run --files <changed files>` (passed; the rebase did not
change this PR's diff).
Known gaps: the same pre-existing hang as in #9114 (zero-row groups in
`torch._grouped_mm` on this machine) keeps the rest of
`test_autoep_expert_activation.py` from running here; the full unit
suite was not run.
Commit ids: the branch was rebased onto #9114 at `6ee0cbb9a` (itself
rebased onto master `b9896d054`, a README-only change) after these runs.
The results labelled e27a91cc9 were measured on the patch-identical
commit c381ff001, whose tree differs only in that README line, and were
not repeated.
## Review fixes
- Codex P1
([thread](https://github.com/deepspeedai/DeepSpeed/pull/9115#discussion_r4621781160)):
staged gradients returned on only some ranks of a ZeRO-3 partition
group. Fixed in #9114 (`6ee0cbb9a`); reproduced here as a ZeRO-3 hang
with that change reverted, and covered by the replicated-expert test for
ZeRO 3.
- Codex P2 (e27a91cc9): the detached weight aliases kept gathered expert
weights allocated until the backward. In a probe emulating ZeRO-3's
release (8 experts, 96 MiB of bf16 weights, one H200), the staged path
kept 98 MiB after the release before the fix and 2 MiB after it with
separate gate/up. With `gate_up_impl="fused"` it keeps 66 MiB, because
the packed gate+up copy is still saved: packing it again in the backward
made the fused staged forward+backward 30% slower at 8 rows per expert
(2.16 -> 2.82 ms per microbatch; 128 experts, hidden 2048, intermediate
768). With the copy kept, timings were unchanged for both variants. The
plain `torch._grouped_mm` path keeps its weights through the views
autograd saves and is not changed.
## Compatibility matrix
| Cell | Status |
| --- | --- |
| ZeRO 3, bf16, expert parallel 1 and 2, `comm` backend | validated
(parity test above; expert parallel 1 by the 2-rank replicated-expert
test and the single-GPU script) |
| ZeRO 0 / 1 / 2 | re-validated by the same parity test |
| ZeRO-3 optimizer / parameter offload, NVMe, hpZeRO, quantized
gradients with staging | not validated |
| DeepEP backend, sequence parallel, multi-node | not validated |
No end-to-end throughput, peak-memory or convergence measurements were
made for this PR; the module-level numbers under Review fixes are the
only ones. Item 3 adds a `data_ptr()` check per weight per forward on
the grouped-GEMM paths and, under ZeRO-3 with an unaligned gathered
weight, a weight-sized copy per forward; its cost was not measured.
---------
Signed-off-by: Zhipeng Wang <zhipeng.rainbowserie@gmail.com>
Co-authored-by: Claude Fable 5.2 <noreply@anthropic.com>